Water Flow Test For Fire Hydrants

There are two types of fire flow tests.
Water flow test for fire hydrants. If the hydrant has a. This is the static pressure p s. Hydrant flow testing verifies water main capabilities. Pitot gauges make it simple to quickly measure the flow of fire hydrants and convert readings in pounds per square inch psi to gallons per minute gpm.
I spent 19 years as a career firefighter before fire protection engineering. As a voluntary consensus standard nfpa 291 2019 covers fire flow testing and marking of hydrants. Right now i m looking at flow test data that flows 86 static 85 static 1007 gpm. Referring to the figure prior to flowing hydrant 1 pressure is measured at hydrant 2.
Hydrant flow tests are required prior to new construction and the installation of fire suppression systems. To ensure that fire hydrants can supply adequate water during an emergency municipalities and other authorities require regular hydrant flow testing. Remove the nozzle cap on the pressure hydrant and attach a pressure gauge to the outlet. 52 fire hydrant flow and pressure tests fire hydrants are tested to determine flow and pressure.
This will be used to gather. These requests help design fire suppression systems. The hydrant test equipment should not restrict the flow of water from the hydrant. A fire flow test is performed for a specific area by using three fire hydrants.
Fire flow tests on water distribution systems exist to determine the rate of flow available at various locations for fire fighting purposes. 1 3 as these tests are to ascertain the volume of water available for fire fighting purposes the hydrant test equipment should attach to the standpipe using fittings in use by the fire service for fire fighting. Locate the test area by choosing the closest hydrant downstream of the building supply line. If you are designing a fire sprinkler.
Fire hydrant flow test analysis equation awwa 2006 p. A cap pressure gauge is placed on one hydrant to record the static pressure. Hydrant capacity test determines the flow rate available from the hydrant and if it will deliver in a fire emergency. I could count on one hand the number of hydrants that didn t flow at least 1500 gpm.
Main capacity test determines the water supply availability in the water main. Water main pressures are recorded by conducting a residual fire flow test per nfpa 291. A hand held pitot pressure gauge is used to measure the residual pressure while the hydrants are flowing. The results provide the water pressure within the distribution system and the pressure during typical demands with no hydrants flowing.
Then hydrant 1 is opened so that water discharges from it. Note any elevation changes from the pressure hydrant to. Request a hydrant flow test. You don t think that s not flowing way more than 1500 gpm as the flow curve progresses.