Warm Lead Roof Construction

In case of warm roofs they have an insulation above the roof deck in this way it keeps the deck warm.
Warm lead roof construction. Where a warm roof is used a ventilation void should be provided between the insulation and the timber decking supporting the lead if there is sufficient height available. Because of this the vcl always sits at the warm side of the. The membrane is then attached to the insulation. This video will demonstrate how to install a cure it grp waterproofing system in a warm roof build up.
Be it a cold or warm roof construction the primary function of a vcl is to keep warm moist air from inside the building inside the building. For guidance on the amount of ventilation required reference should be made to british standards 5250 and 6229. Cold roof voids are typically required to be ventilated. Put simply a warm flat roof has insulation of some kind packed into every available void and a cold flat roof allows air to circulate.
Warm leads is your introduction to just about any kind of construction lead that you may be looking for including but not limited to. Correctly laid lead roof greyfriars roofing note the height of steps between bays the rolled joints and adequate overlaps problems. When building a flat roof it is vital that a degree of falls is built into the construction to ensure rainwater run off. It is usually the most acceptable type of construction for domestic possessions and belongings as it avoids the need for aeration of the roof construction.
It s the first line of defence against high vapour pressure air entering the roof structure and causing interstitial condensation. Others would treat even steeper pitches as flat roofs. More about lead as a building material. Solar leads roofing leads paint leads hvac leads air conditioner leads telemarketing leads residential leads commercial leads solar appointment leads elocal leads exclusive leads networx leads modernize leads craftjack leads plumbing leads house.
In pitched roof construction thermal insulation can be placed horizontally at ceiling level cold roof. The definition of a flat roof according to bs 6229 is having a pitch less than 10 o to the horizontal however some in the industry would consider up to 15 o as their definition of a flat roof. It should also be noted that a warm roof adds height to a flat roof and so cannot be used on balconies and extensions with doors that lead onto the roof. For more information on any commercial industrial roofing services contact us at roofing consultants group 0800 046 1500.